AGM Deep Cycle · Series RDC
Endurance for frequent charge/discharge cycling.
Designed for persistence, the RDC Series is optimized for severe cyclic service under the EUROBAT 'Cycle Service' classification. Unlike standby batteries, it uses specialized active material that allows it to exceed 400 cycles at 80% Depth of Discharge (DOD). Its internal construction is denser, preventing stratification and ensuring stability after repetitive use. With a 12-year design life, it is the ultimate technical solution for light electric vehicles and solar systems requiring superior 'muscle' and high wear resistance.
Request a quote Models (19) PDF
CE CERTIFIED ISO 9001 / 14001 IEC 60896-21/22 JIS C8704 GB/T19639
Each model links to its datasheet with discharge tables, dimensions and charge parameters. Rated capacity at 25 °C; C20 = 20-hour rate.
| Model | Nominal Voltage | Capacity | Length (mm) | Width (mm) | Height (mm) | Weight (kgs) | Terminal |
|---|---|---|---|---|---|---|---|
| RDC2-800 (formerly RKC2-800) | 2 V | 800 Ah (C10) | 410 | 175 | 330 | 51 | F10 |
| RDC2-1000 (formerly RKC2-1000) | 2 V | 1000 Ah (C10) | 475 | 175 | 330 | 60 | F10 |
| RDC6-200G (formerly RKC6-200G) | 6 V | 200 Ah (C10) | 264 | 180 | 247 | 30 | F12 |
| RDC6-235 (formerly RKC6-235) | 6 V | 235 Ah (C10) | 260 | 180 | 272 | 36 | F12 |
| RDC6-300 (formerly RKC6-300) | 6 V | 300 Ah (C10) | 295 | 178 | 350 | 46 | F13 |
| RDC6-380G (formerly RKC6-380G) | 6 V | 400 Ah (C20) | 295 | 180 | 406 | 53 | F12 |
| RDC12-12 (formerly RKC12-12) | 12 V | 12 Ah (C10) | 151 | 98 | 95 | 3.45 | F11 |
| RDC12-33 (formerly RKC12-33) | 12 V | 33 Ah (C10) | 195 | 130 | 155 | 10.2 | F11 |
| RDC12-55 (formerly RKC12-55) | 12 V | 55 Ah (C10) | 229 | 138 | 208 | 16.5 | F11 |
| RDC12-65 (formerly RKC12-65) | 12 V | 65 Ah (C10) | 350 | 167 | 179 | 20.5 | F14 |
| RDC12-75 (formerly RKC12-75) | 12 V | 75 Ah (C10) | 260 | 169 | 208 | 22.5 | F11 |
| RDC12-80 (formerly RKC12-80) | 12 V | 80 Ah (C10) | 350 | 167 | 179 | 23 | F11 |
| RDC12-90 (formerly RKC12-90) | 12 V | 90 Ah (C10) | 306 | 169 | 208 | 27.5 | F14 |
| RDC12-100 (formerly RKC12-100) | 12 V | 100 Ah (C10) | 328 | 171 | 214 | 30 | F14 |
| RDC12-120 (formerly RKC12-120) | 12 V | 120 Ah (C10) | 406 | 173 | 227 | 34 | F12 |
| RDC12-134 (formerly RKC12-134) | 12 V | 134 Ah (C10) | 410 | 176 | 227 | 34 | F12 |
| RDC12-150 (formerly RKC12-150) | 12 V | 150 Ah (C10) | 485 | 172 | 240 | 44 | F13 |
| RDC12-250 (formerly RKC12-250) | 12 V | 250 Ah (C10) | 520 | 269 | 220 | 70 | F13 |
| RDC12-260 (formerly RKC12-260) | 12 V | 260 Ah (C10) | 520 | 269 | 220 | 72 | F12 |
| Component | Material |
|---|---|
| Container | ABS (Flame Retardant Optional) |
| Cover | ABS (Flame Retardant Optional) |
| Electrolyte | Sulphuric acid |
| Negative | Lead |
| Positive | Lead dioxide |
| Safety Valve | Rubber |
| Sealant | Epoxy Resin |
| Separator | Fibre Glass |
| Terminal | Copper |
Our team of experts is ready to help you find or design the perfect energy solution. Contact us for a personalized consultation.
Contact Our Experts