The ROS2-800 is a 2 V, 800 Ah (10-hour rate) OPzS lead-acid battery from the Rekoser OPzS (Flooded) series. It measures 191 × 210 × 645 mm and weighs 44 kg, with F10 terminals. It stores 1.6 kWh and delivers up to 4000 A. The energy tank. 20+ years of proven service life. Typical applications: Solar/Wind Energy Systems, Electrical Substations, Telecommunications and Base Stations and Railway Signaling and Infrastructure.
Formerly RKS2-800.
| Nominal Voltage | 2 V |
|---|---|
| Capacity (25ºC) | 800 Ah (C10) |
| Energy | 1600 Wh |
| Weight | 44 kg |
| Terminal | F10 |
| Dimensions | 191 × 210 × 645 mm |
ROS2-800
OPZS (FLOODED)Constant Discharge Ratings (A) at 25ºC
| F.V / Time | 5MIN | 10MIN | 15MIN | 30MIN | 1HR | 3HR | 5HR | 10HR | 20HR | 100HR |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.90 V | 319A | 290A | 264A | 258A | 239A | 151A | 111A | 72.8A | 40A | 10.2A |
| 1.85 V | 345A | 330A | 325A | 323A | 272A | 167A | 130A | 76A | 41.8A | 10.8A |
| 1.80 V | 550A | 528A | 517A | 350A | 350A | 205A | 138A | 80A | 44A | 11.2A |
| 1.75 V | 661A | 634A | 614A | 390A | 390A | 212A | 142A | 82.4A | 46.2A | 11.4A |
Constant Discharge Ratings (W) at 25ºC
| F.V / Time | 5MIN | 10MIN | 15MIN | 30MIN | 1HR | 3HR | 5HR | 10HR | 20HR | 100HR |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.90 V | 619W | 563W | 506W | 460W | 460W | 329W | 238W | 150W | 80.6W | 22W |
| 1.85 V | 669W | 642W | 623W | 523W | 523W | 344W | 265W | 163W | 87.8W | 22.9W |
| 1.80 V | 1068W | 1025W | 878W | 686W | 686W | 438W | 302W | 176W | 91.3W | 23.5W |
| 1.75 V | 1282W | 1230W | 901W | 691W | 691W | 463W | 316W | 183W | 93.5W | 23.7W |
ROS2-800
OPZS (FLOODED)| Nominal Voltage | 2 V |
|---|---|
| Capacity (25ºC) | 800 Ah (C10) |
| Energy | 1600 Wh |
| Cell number | 1 |
| Charge Voltage (25°C) | Cycle use: 2.35-2.40V (-5mV/ºC/cell) Float use: 2.21-2.25V (-3mV/ºC/cell) |
| Max. Charge Current | 160 A |
| Max. Discharge Current | 4000 A |
| Internal Resistance | 0.35 mΩ |
| Self Discharge | 3 % of capacity per month at 20 °C |
| Capacity Affected by Temperature | 40 °C: 102 %, 25 °C: 100 %, 0 °C: 85 %, -15 °C: 65 % |
| Component | Material |
|---|---|
| Container | SAN |
| Cover | ABS (Flame Retardant Optional) |
| Electrolyte | Sulphuric acid |
| Negative | Lead |
| Positive | Lead dioxide |
| Safety Valve | Rubber |
| Sealant | Epoxy Resin |
| Separator | Fibre Glass |
| Terminal | Copper |
ROS2-800
OPZS (FLOODED)To ensure optimal performance and maximize the lifespan of your REKOSER ROS2-800 battery, follow these assembly and connection guidelines.
Before proceeding, ensure the receptacle or cabinet of your equipment complies with the unit's physical measurements:
Maintenance: Check the electrolyte level and top up only with distilled or demineralised water.
Position: Always upright.
Ventilation: Install in a ventilated room: hydrogen is released during charging.
Storage: Store charged, in a cool and dry place, and recharge periodically.
ROS2-600 (2 V · 600 Ah) · ROS2-1200 (2 V · 1200 Ah) · See all ROS series models