RSI-HY-3PH Three-phase hybrid inverter with ATS for smart energy management. Works with PV Solar + Grid + Battery + Generator.
Ask quotation Rekoser Rekoser inverters
|
Model |
RSI-10K-3PH |
RSI-20K-3PH |
RSI-30K-3PH |
RSI-40K-3PH |
RSI-50K-3PH |
RSI-60K-3PH |
RSI-80K-3PH |
RSI-100K-3PH |
RSI-120K-3PH |
RSI-160K-3PH |
RSI-200K-3PH |
|
Capacity (KVA) |
10KVA |
20kVA |
30kVA |
40kVA |
50kVA |
60kVA |
80kVA |
100kVA |
120kVA |
160kVA |
200kVA |
|
Power ( Watts ) |
8kW |
16kW |
24kW |
32kW |
40kW |
48kW |
64kW |
80kW |
96kW |
128kW |
160kW |
Grid |
Max input current (A) |
31 |
41 |
61 |
81 |
101 |
121 |
161 |
201 |
241 |
321 |
401 |
Type |
Three phase, 3L+N+G |
|||||||||||
Line-Neutral Voltage |
220/230/240VAC±25% (100/110/120VAC is optional) |
|||||||||||
Line-Line Voltag |
380/400/415VAC±25% (200/208/220VAC is optional) |
|||||||||||
Input frequency |
50/60Hz±5% |
|||||||||||
Charge voltage |
432V±1% |
|||||||||||
Charge current power |
capacity *20% |
|||||||||||
PV |
PV input range |
560VDC~800VDC |
||||||||||
Charge current |
depends on inverter capacity |
|||||||||||
Battery |
Type |
Maintenance free lead-acid battery (other type battery need customize ) |
||||||||||
Battery voltage |
384Vdc |
|||||||||||
Battery capacity |
According to backup time |
|||||||||||
Battery low voltage protection |
>336V |
|||||||||||
Inverter |
Inverter output waveform |
Pure sine wave, THD<3% (linear load) |
||||||||||
Line-Neutral Voltage |
220/230/240VAC±2% (100/110/120VAC is optional) |
|||||||||||
Line-line Voltage |
380/400/415VAC±2% (200/208/220VAC is optional) |
|||||||||||
Frequency |
50/60Hz±0.5% |
|||||||||||
Dynamic feature |
Inverter output transient dynamic range less than±5%,recovery time <20mS |
|||||||||||
Crest factor |
3:1 |
|||||||||||
Overload protection |
(Inverter output)125% overload, delay 1mins protect, 150% overload, immediate protect |
|||||||||||
Inverter efficiency |
>90% ( 100% load ) |
|||||||||||
System |
Transfer time |
<0.5ms ( inverter--bypass ) |
||||||||||
Protection |
Output short circuit, overload, overvoltage, under voltage, over temperature etc protection, have audible and visual alarm |
|||||||||||
Display |
LCD display input and output voltage, output current, the inverter voltage, frequency, output current, battery voltage, PV voltage, PV charging current, temperature mode, flowcharts, current work status, event record and system information |
|||||||||||
Operating environment |
Temperature 0-40℃ |
|||||||||||
Relative humidity |
30%-95% |
|||||||||||
Work sequence |
Solar-Grid-Battery or Solar –battery-Grid, Can choose one of the mode via LCD panel |
|||||||||||
Operation altitude (max) |
<1000 meters ( per increase 100 meters power decrease 1%, at most 4000 meters ) |
|||||||||||
Computer communicate interface |
RS232/RS485 |
|||||||||||
Cooling method |
force-air cooling |
|||||||||||
Size W×D×H (unit: mm) |
600*620*1250 |
700*620*1530 |
980*800*1800 |
1380*950*1800 |
||||||||
Weight (kg) |
236 |
265 |
342 |
407 |
485 |
506 |
770 |
913 |
937 |
1440 |
1760 |