RSI-LF+ series is a pure sine wave low frequency solar off-grid inverter with built-in MPPT solar charge controller of 60A/120A.
The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.
MODEL | RSI-4K-LF+ | RSI-5K-LF+ | RSI-6K-LF+ | RSI-8K-LF+ | RSI-10K-LF+ | RSI-12K-LF+ | ||
Nominal Battery System Voltage | 24V | 48V | 48V | 48V | 48VDC | 48VDC | 48VDC | |
INVERTER OUTPUT | ||||||||
Rated Power | 4KW | 5KW | 6KW | 8.0KW | 10.0KW | 12.0KW | ||
Surge Rating (20ms) | 12KW | 15.0KW | 18.0KW | 24.0KW | 30.0KW | 36.0KW | ||
Capable Of Starting Electric Motor | 2HP | 2HP | 3HP | 4HP | 5HP | 6HP | ||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||
Nominal Output Voltage RMS | 220V/230V/240VAC(+/-10% RMS) | |||||||
Output Frequency | 50Hz/60Hz +/-0.3 Hz | |||||||
Inverter Efficiency(Peak) | >85% | >88% | ||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 0.8 | |||||||
Typical Transfer Time | 10ms(max) | |||||||
AC INPUT | ||||||||
Voltage | 230VAC | |||||||
Selectable Voltage Range | 154~272VAC(For Personal Computers) | |||||||
Frequency Range | 50Hz/60Hz (Auto sensing) | |||||||
BATTERY | ||||||||
Minimum Start Voltage | 20.0VDC/21.0VDC for24VDC mode (40.0VDC/42.0VDC for 48VDC mode) | |||||||
Low Battery Alarm | 21.0VDC+/-0.3V for 24VDC mode (42.0VDC+/-0.6V for 48VDC mode) | |||||||
Low Battery Cutoff | 20.0VDC+/-0.3V for 24VDC mode (40.0VDC+/-0.6V for 48VDC mode) | |||||||
High Voltage Alarm | 32.0VDC+/-0.3V for 24VDC mode (64.0VDC+/-0.6V for 48VDC mode) | |||||||
High Battery Voltage Recover | 31.0VDC+/-0.3V for 24VDC mode (62.0VDC+/-0.6V for 48VDC mode) | |||||||
Idle Consumption-Search Mode | <25W when power saver on | <25W when power saver on | ||||||
AC CHARGER | ||||||||
Output Voltage | Depends on battery type | |||||||
Charger AC Input Breaker Rating | 30A | 30A | 30A | 40A | 50A | 63A | ||
Overcharge Protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | |||||||
Maximum Charge Current | 65A | 40A | 35A | 40A | 70A | 80A | 100A | |
BTS | ||||||||
Continuous Output Power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | |||||||
BYPASS & PROTECTION | ||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
Bypass Breaker Rating | 40A | 80A | 80A | 80A | ||||
Max Bypass Current | 40Amp | 80Amp | ||||||
SOLAR CHARGER | ||||||||
Maximum PV Charge Current | 60A | 60A(120A Optional) | ||||||
DC Voltage | 24V/48V Auto work | 48V | ||||||
Maximum PV Array Power | 1600W | 3200W | 3200W | 3200W | 3200W(6400W for 120A Optional) | |||
MPPT Range @ Operating Voltage(VDC) | 32-145VDC for 24V mode,64-147V for 48V mode | 64~147VDC | ||||||
Maximum PV Array Open Circuit Voltage | 147VDC | |||||||
Maximum Efficiency | >98% | |||||||
Standby Power Consumption | <2W | |||||||
MECHANICAL SPECIFICATIONS | ||||||||
Mounting | Wall mount | |||||||
Dimensions (W*H*D) | 620*385*215mm | 670*410*215mm | ||||||
Net Weight (Solar CHG) kg | 36 | 41 | 44 | 69+2.5 | 75.75+2.5 | 75.75+2.5 | ||
Shipping Dimensions(W*H*D) | 755*515*455mm | 884*618*443mm | ||||||
Shipping Weight (Solar CHG) kg | 56 | 61 | 64 | 89+2.5 | 95.5+2.5 | 95.5+2.5 | ||
OTHER | ||||||||
Operation Temperature Range | 0°C to 40°C | |||||||
Storage Temperature | -15°C to 60°C | |||||||
Audible Noise | 60dB MAX | |||||||
Display | LED+LCD | |||||||
Loading(20GP/40GP/40HQ) | 140pcs / 280pcs / 320pcs |